Products

  • GDYT-10/100  Partial Discharge Testing System 10kVA/100kV

    GDYT-10/100 Partial Discharge Testing System 10kVA/100kV

    This set of equipment is mainly used for partial discharge measurement and other scientific experimental research.

  • TWR-S  Transformer Turns Ratio Tester

    TWR-S Transformer Turns Ratio Tester

    TWR-S Transformer Turns Ratio Tester  can be used for three-phase transformer testing in power systems, especially for Z-type winding transformers, rectifier transformers and Scott, reverse Scott, and balanced transformer testing in railway electrical systems. It is an ideal transformer ratio group polarity tester for power systems, transformer manufacturers and railway electrical systems.

  • GDKC-15D  Circuit Breaker Analyzer

    GDKC-15D Circuit Breaker Analyzer

    High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15D circuit breaker analyzer is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. 

  • GDYL-12kV/100pF  Calibration Standard

    GDYL-12kV/100pF Calibration Standard

    The Standard Capacitor is a calibration instrument. It is standard capacitor for tan delta. When calibrating the test result, it can be tested as test object. User can compare the measured test result with former result.

  • GDSL-D-5000A/6V Primary Current Injection Test Set

    GDSL-D-5000A/6V Primary Current Injection Test Set

     Primary Current Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, distribution stations, electrical manufacturing and research institutes, with the features of small size, light weight, easy to use and maintenance. 

  • GD-875/877 Thermal Infrared Camera

    GD-875/877 Thermal Infrared Camera

    GD-875/877 infrared camera uses 25μm 160*120 detector, temperature measurement range -20℃–+ 350, 3.5inch TFT LCD screen.

     

     

     

  • GDWG-III SF6 Gas Leakage Detector

    GDWG-III SF6 Gas Leakage Detector

    GDWG-III SF6 gas leakage detector, with non-dispersed infrared (NDIR) technology, is mainly used to pinpoint and measure SF6 leakage on GIS and refilling equipment within power industry. 

     

  • GDWS-311RC SF6 Gas Dew Point Tester

    GDWS-311RC SF6 Gas Dew Point Tester

    GDWS-311RC is ideal instrument when it is necessary to test water content of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument

     

  • GDWG-IV SF6 Gas Leak Detector(IR Series)

    GDWG-IV SF6 Gas Leak Detector(IR Series)

    GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration. 

  • GDSF-311WPD 3-In-1 SF6 Gas Analyzer

    GDSF-311WPD 3-In-1 SF6 Gas Analyzer

    GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP®  series sensors produced by Finland Vaisala company. 

  • GDWG-V SF6 Gas Leak Detector (IR type, Double display)

    GDWG-V SF6 Gas Leak Detector (IR type, Double display)

    GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration.

  • GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device

    GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device

    GDQC-16A Gas Vacuum Pumping and Filling Device is mainly used as auxiliary equipment of gas equipment GCBT, GIS, SF6 during installing, debugging and repairing in various power supply companies, power transmission engineering companies, power plants, ultra high voltage transmission,  SF6 gas electrical switch manufacturing plant and other departments.

     